Avante True 12T Twelve-Channel EKG Machine with Touch Screen
- Input circuit: Defibrillation protection built-in
- Lead: Standard 12 leads
- Acquisition mode: 12-channel simultaneous
- A/D converter: 24 bits
- Input voltage range: ±5mVp-p
- Time constant:: >3.2s
- Frequency response: 0.05Hz-150Hz
- Calibration voltage: 1mV±2%
Description
DETAILS
Avante True ECG 12T EKG Machine -Excellent Cost Performance with Large Touch Screen Display
- Preview report for both real-time ekg printing and file storage
- Average template ekg machine waveform with accurate interpretation tested with CSE DATABASE, which supplies measurement, diagnosis, and Minnesota code
- Doctor can edit the ekg printing style, printing speed, sensitivity, and used filter to get better waveforms instead of repeating patient examination
- Freeze and review waveform timely to grasp every arrythmia
- Internal storage including waveforms, measurement and diagnosis which could also be enlarged by flash disk or PC hard disk.
- Features 8.4″ color touch-screen
- Compact, lightweight design with carrying handle
- Digital filters for baseline, AC and EMG interference resistence
- Standby mode for energy saving
- EKG Machine has Built-in Ethernet and RS-232 interfaces for PC connection
- USB port for data transmission and external jet-printer connection
- Internal Memory – 200 Tests
- Built-in rechargeable Li-ion battery: voltage=14.4V – 5 hours, 400 Reports, 320 × 240 dots monochrome LCD
SPECIFICATIONS
General
- Input circuit: Defibrillation protection built-in
- Lead: Standard 12 leads
- Acquisition mode: 12-channel simultaneous
- A/D converter: 24 bits
- Input voltage range: ±5mVp-p
- Time constant:: >3.2s
- Frequency response: 0.05Hz-150Hz
- Calibration voltage: 1mV±2%
- Sensitivity: 2.5, 5, 10, 20, 10/5, AGC (mm/mV)
- Input impedance: >50M Ω (10Hz)
- Input circuit current: <10nA
- Noise level: <12.5 μ Vp-p
- Patient leakage current: <10 μ (220V-240V)
- Patient auxiliary current: <0.1 μ A (DC)
- Filters:
- EMG filter 25Hz/35Hz/45Hz/OFF
- Anti-baseline drift 0.05/0.15/0.25/0.5Hz
- Low-pass filter 150Hz/100Hz/ 75Hz
- AC filter 50Hz/60Hz
- CMRR >121 dB
- Recording modes Auto/manual/rhythm
- Rhythm lead Single lead or three leads selectable
- Safety Standard IEC I/CF
- Power supply AC:100-240V, 50/60Hz
- Battery Built-in rechargeable Li-ion battery: voltage=14.4V, for about 400 copies ECG printing
- Recorder Thermal printer
- Recording paper Roll and z-fold 216mm, 210mm width
- Recording speed 5mm/s, 10mm/s12.5mm/s, 25mm/s,50mm/s (±3%)
- Dimensions 420mm × 330mm × 120mm
- Display 800 × 600 dots LCD
- External input >100K Ω, sensitivity 10mm/V±5
- External output
- Communication interface Ethernet or RS232