Complete cardiovascular imaging system delivers advanced image quality, patient positioning
The GE Innova 2100 is a complete cath/angio system that offers clinicians easy patient positioning, advanced image quality, and innovative dose management. The Innova 2100 provides consistently high imaging performance while allowing clinicians to complete interventional and diagnostic angiography procedures.
For more information on the GE Innova 2100 Cath/Angio System, available refurbished through Avante Health Solutions, contact an Avante representative today.
Features
- C-arm unit also includes table-side control boxes and control cabinet.
- GE Omega IV angio table with weight limit up to 450 pounds, features “floating top” for flexible patient positioning.
- Table top height adjustment measures 30.5 to 42.5 inches.
- Table Side User Interface (TSUI): Smart box or Smart handle.
- Table Side Status Control (TSSC) and Innova central touchscreen.
- Innova Console includes the following components:
- Innova Digital Color LCD Monitor
- Exposure Hand Switch
- Innova Console
- Console keyboard and mouse
- X-ray high-frequency and high-voltage generator.
- X-ray tube and collimator.
- Image detection unit.
- In-room and control monitors.
- DICOM worklist compatibility.
- The external chiller provides continuous water cooling.
- Ceiling and table-mounted radiation protection.
- Accessories: table panning device, arm support, arm board, dual footswitch with table unlock, IV pole and mount, Velcro quick strap, tilting table, footrest/shoulder rests — ask your Avante representative for more information.
Available Options
- Injector interface
- Table head extender
- Diamentor dose monitoring
- Innova IVUS
- Downscan
- Innova central touchscreen
- Innova IQ table
- UPS
- Wall-mount suspension
- In-room 3D
- CRT monitor suspension
- TSUI options: Smart handle, smart box, second smart box, second Smart handle, second TSSC, remote TSSC, remote smart handle, remote smart box
- OMEGA table foot end rail
- Second footswitch with cover
- Workstation (including power supply, imaging processing system, TV display system)
- Remote Stand
- Multiple software options — ask your Avante representative for more information
SPECIFICATIONS
Generator
- Nominal output power: 100 kW
- Max kW of generator’s output when loading time is 0.1s, 100kW
- Range of frequency used by the high-voltage generator: 20 kHz – 60 kHz
- kV-mA range: kV from 40 kV to 125 kV | Maximum mA: 1000 mA
- Large focus: Maximum mA: 1000 mA | Maximum power: 100 kW
- Small focus: Maximum mA: 400 mA | Maximum power: 48 kW
- Compressed focus: Maximum mA: 200 mA | Maximum power: 16 kW
Gantry
- L-arm rotates on its vertical axis +/- 100° (+/- 95° motorized limit set)
- Offset C-arm (pivot) permits -117°/+105° RAO/LAO rotation
- The C-arm permits 50° cranial and 45° caudal angulation of the imaging system
- SID Fully motorized (8.9 cm/s – 3.5 in/s)
- SID range of 85 cm to 119 cm (33.5 to 46.8 in) for Innova 2100-IQ. Travel distance of 34 cm (13.4 in)
- X-ray tube Focal Spot to Isocenter 72 cm (28.3 in)
- Isocenter to the floor of 107 cm (42 in)
Omega IV Table
- Tabletop filtration: Less than 0.85 mm aluminum equivalent
- Mattress: 2.5 cm (1 in) mattress + slicker: less than 0.70 mm aluminum equivalent
- Maximum patient weight: 204 kg (450 lb)
- Maximum table load: 204 kg (450 lb)
- Tabletop length: 300 cm (118 in)
- Tabletop width: 48 cm (18 in) in Patient Trunk Area – 67 cm (26.4 in) max
- Horizontal float movement: 8-way
- Horizontal motorized movement: N/A
- Longitudinal speed: N/A
- Longitudinal travel: 110 cm (43.3 in)
- Equivalent fluoroscopic coverage: 126 cm (49.6 in)
- Transverse travel: manual +/- 14 cm (+/- 5.5 in)
- Vertical travel: 30 cm (12 in)
- Vertical travel above floor: 2 cm/s (0.8 in/s) at 50 Hz | 2.5 cm/s (1 in/s) at 60 Hz
- Table base: 61 cm x 52 cm (24 in x 20.5 in)
- Table rotation: +/- 180°
Innova Digital
- DICOM V3.0 implementation
- Store up to 4,000 sequences and photos
Innova Imaging
- Available input screen size of detector (cm): 0 Mag – 20 | 1 Mag – 17 | 2 Mag – 15 | 3 Mag – 12
- Horizontal center resolution (not less than); (lp/mm): 0 Mag – 2.5 | 1 Mag – 2.5 | 2 Mag – 2.5 | 3 Mag – 2.5
- Hi-resolution 1249 line analog video output
- Hi-resolution 1249 line motor, 50 Hz
- Visibility range: 4 cm – 13 cm (using 20 cm PMMA and 16 cm PMMA step wedge)